DOI:
上海电力大学学报:1994,10(1):35-39
本文二维码信息
码上扫一扫!
水冷壁管高温硫腐蚀试验研究及防止措施
(浙江大学)
Experimental Study on High Temperature Sulfur Corrosion of Water -Cold Tube and Protection Measures
(Zhe Jiang Oniversity)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 969次   下载 546
投稿时间:1993-09-13    
中文摘要: 本文阐述了高温硫腐蚀的机理,通过用水冷枪取样对某电厂125MW机组420t/h锅炉燃烧器高度水冷壁区域气氛、灰样、温度场以及时腐蚀减薄水冷壁管爆破口切片的金相和元素能谱分析,并进行了冷炉试验和加装贴墙风的冷模试验,试验结果表明:该炉水冷壁减薄主要是由高温硫腐蚀引起,据此提出了相应的防止措施。
中文关键词: 水冷壁  高温硫腐蚀
Abstract:In this paper a mechanism of high temperature is presented, and a method of measuring temperature fild of boiler furance is introduced by use of water-cold equipment to capture and gas around water cold tube in burner's height. The metallographic analysis, the element energy spectrum analysis, the test of cold furnace and the test of cold model coith air near weter - cold tubes have been engaged in. The experiniental results shows that the reduction of water- cold tube wall's thickness is mainly caused by high temperature sulfur corrosion. At last some pratection measures are put forward.
文章编号:19940105     中图分类号:    文献标志码:
基金项目:
引用文本:
潘卫国,池作和,朱珍锦,等.水冷壁管高温硫腐蚀试验研究及防止措施[J].上海电力大学学报,1994,10(1):35-39.
Pan Weigo,Zhi Zhouhe,Zhu Zhejin,et al.Experimental Study on High Temperature Sulfur Corrosion of Water -Cold Tube and Protection Measures[J].Journal of Shanghai University of Electric Power,1994,10(1):35-39.