轴向位移保护接点的组合及可靠性
(上海电力学院自动控制系)
Combination and Reliability of Protective Contacts at Axial Displacement
(Department of Autometic Control Engineering)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 981次   下载 438
投稿时间:1995-05-08    
中文摘要: 热工保护接点动作的可靠性关联着热力设备运行在异常工况下的安全性。但热工保护接点都存在误动作或拒动作的失效可能。本文以汽机轴向位移保护为例子,提出了保护接点在不同组合方案下误动作、拒动作率、MTBF值等计算方法,并探讨了最佳接点组合方案,以供设计和调试人员工作中参考。
中文关键词: 误动作  拒动作  工况概率  失效率
Abstract:The raliability of thermo—thchnique protective contacts in operation is relevant to the safety of thermodynamic equipment in runnig at abnormal status. But there are possibility of both incorrect operation and refusal to operte of thermo-thchnique protective contacts.Taking the protection at axial displacement of turbine for example, this paper presents the methods of calculating failure rate of incorrect operation and refusal to operate and MTBF of protective contacts in various combination schemes, and investigates optimum schemes of combining contacts for reference of designers and regulator; in work.
文章编号:19950305     中图分类号:    文献标志码:
基金项目:
引用文本:
吴文德.轴向位移保护接点的组合及可靠性[J].上海电力大学学报,1995,11(3):37-47.
Wu Wende.Combination and Reliability of Protective Contacts at Axial Displacement[J].Journal of Shanghai University of Electric Power,1995,11(3):37-47.