活性污泥法处理柠檬酸酸洗锅炉废水研究
(1.上海电力学院;2.上海电力局教育培训中心;3.南京电力自动化设备厂)
Treatment of Boiler's Waste Water with Activated Sludge
(1.Shanghai Institute of Electric Power;2.Educational & Training Centre of Shanghai Municipal Electric Power Bureau;3.Nanjing Electric Power Automation Equipment General Factory)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 946次   下载 542
投稿时间:1996-07-19    
中文摘要: 本文采用东区污水处理厂活性污泥作为驯化用种泥,其生活污水作为驯化用水。控制污泥沉降比SV3030%左右,pH 7.5~8.0,溶解氧DO 4.0~5.0mg/L,水温15~25℃,驯化并处理上海石洞口发电厂1000t/h直流炉柠檬酸清洗废水。试验结果表明:当进口CODcr浓度在2000mg/L以下时,CODcr的去除率可达85~90%,效果较好。
Abstract:Taking the activated sludge of Shanghai East - part Sewage Treatment Plant as domesticating sludge seed, and the domestic sewage of that as domesticating water, tests have been made under the condition that the subsidence ratio of sludge was controlled around 30% (SV30), pH 7.5 - 8.0, dissolved oxygen (DO) 4.0 - 5.0 mg/L, water temperature 15 - 25 C. The citric acid waste water arising from washing the once-through boiler of 1000t/h in Shanghai Shidongkou Power Plant has been treated and domesticated. The result indicates that when the inlet CODcr concentration is lower than 2 000 mg/L, the removing ratio of CODcr can be 85 - 90%, so the effect is good.
文章编号:19960405     中图分类号:    文献标志码:
基金项目:
引用文本:
吴怀兆,贾慧琍,朱士圣.活性污泥法处理柠檬酸酸洗锅炉废水研究[J].上海电力大学学报,1996,12(4):26-33.
Wu Huai-zhao.Treatment of Boiler's Waste Water with Activated Sludge[J].Journal of Shanghai University of Electric Power,1996,12(4):26-33.