本文已被:浏览 825次 下载 477次
投稿时间:1998-09-21
投稿时间:1998-09-21
中文摘要: 纯铁经过十八烷基胺处理后其耐蚀性随十八烷基胺浓度的增加而增大,但达到一定浓度之后,再增加十八烷基胺的浓度,其耐蚀性反而会有所下降.高压釜内壁覆盖的十八烷基胺不易擦去,这会影响实验结果,可采用多次放空的办法来消除对试验的影响.
Abstract:With increasing concentration of octadecylamine, the corrosion resistance of pure iron ini- tially increases and then decreases. The experiments at our laboratory show the optimum concentration of octadecylamine is around 25 mg压.A considerable amount of octadecylamine remained on the autoclave wall and made an import on the results, which must be eleminated by means of multi-releasing
keywords: octadecylamine iron steel autoclave
文章编号:19980406 中图分类号: 文献标志码:
基金项目:华东电力集团公司资助
引用文本:
廖强强,周国定,葛红花,等.高压釜内壁覆盖的十八烷基胺对成膜试验的影响[J].上海电力大学学报,1998,14(4):34-38.
Liao Qiangqiang,Zhou Guoding,Ge Honghua,et al.Influence of Octadecylamine on Autodave Inner Wall upon Filming Tests[J].Journal of Shanghai University of Electric Power,1998,14(4):34-38.
廖强强,周国定,葛红花,等.高压釜内壁覆盖的十八烷基胺对成膜试验的影响[J].上海电力大学学报,1998,14(4):34-38.
Liao Qiangqiang,Zhou Guoding,Ge Honghua,et al.Influence of Octadecylamine on Autodave Inner Wall upon Filming Tests[J].Journal of Shanghai University of Electric Power,1998,14(4):34-38.