本文已被:浏览 1531次 下载 822次
投稿时间:2004-09-07
投稿时间:2004-09-07
中文摘要: 根据泵/风机在不同工况下运行的性能与特点,分析变流量运行时,泵/风机流量、扬程(压头)、功率与转速间的关系,提出了变流量运行时,泵/风机采用变频技术的节能原理及经济效益.以某电厂鼓风机系统为例,分析比较了电厂鼓风机采用变频调节时的特性、耗能情况及其经济性.
Abstract:Based on the performance and characteristics of pump/fan, this paper analyzes the relationship between flow quantity,head,power and rotate speed.Application of variable frequency speed-control in pump/fan system is introduced. The traits, energy consumption and the economical features of the Pump/fan using frequency speed-control are analyzed and compared.
文章编号:20050105 中图分类号: 文献标志码:
基金项目:
引用文本:
李芳芹,任建兴.变频技术在电厂泵与风机系统中应用的节能分析[J].上海电力大学学报,2005,21(1):17-20.
LI Fang-qin,REN Jian-xing.Analysis of Energy-Conservation on Application of Variable Frequency Technology in Pump and Fan System in Power Plants[J].Journal of Shanghai University of Electric Power,2005,21(1):17-20.
李芳芹,任建兴.变频技术在电厂泵与风机系统中应用的节能分析[J].上海电力大学学报,2005,21(1):17-20.
LI Fang-qin,REN Jian-xing.Analysis of Energy-Conservation on Application of Variable Frequency Technology in Pump and Fan System in Power Plants[J].Journal of Shanghai University of Electric Power,2005,21(1):17-20.