本文已被:浏览 1002次 下载 501次
投稿时间:2010-09-28
投稿时间:2010-09-28
中文摘要: 通过对各种耐压试验的分析,提出采用振荡波交流耐压试验作为电缆竣工试验。在此基础上,设计了振荡波的耐压试验系统电路,并利用PSPICE软件对所设计的电路进行了仿真分析。分析结果表明,所设计的电路能产生良好的试验波形,满足试验要求。
Abstract:As the XLPE power cables are used widely in power system,withstanding voltage test is more and more important for the reliable operation of the cable.By analyzing all kinds of withstanding voltage methods,oscillating wave test system is very suitable for cable to do field test.The whole circuit of oscillating wave test system is introduced and smiulated to analyze the feasibility of circuit.The results of analysis show that a good oscillating wave can be generated on the cable by
the circuit,and parameters of oscillating wave are consistent with demand.
文章编号:20110202 中图分类号: 文献标志码:
基金项目:
Author Name | Affiliation | |
CHEN Jiong | Shanghai University of Electric Power, Shanghai 200090, China | chenjiong770516@163.com |
WANG Mingyan | Shanghai Energy Sources CO. Ltd., Shanghai 221611, China |
引用文本:
陈炯,王明炎.振荡波交流耐压试验系统[J].上海电力大学学报,2011,27(2):107-109,137.
CHEN Jiong,WANG Mingyan.Study of the Oscillating Wave Pressure Test System[J].Journal of Shanghai University of Electric Power,2011,27(2):107-109,137.
陈炯,王明炎.振荡波交流耐压试验系统[J].上海电力大学学报,2011,27(2):107-109,137.
CHEN Jiong,WANG Mingyan.Study of the Oscillating Wave Pressure Test System[J].Journal of Shanghai University of Electric Power,2011,27(2):107-109,137.