本文已被:浏览 1192次 下载 877次
投稿时间:2011-05-26
投稿时间:2011-05-26
中文摘要: 分析了5.12汶川地震中电网的震害特点和震害原因,阐述了我国电力系统抗震研究的现状,以及各类电力设施在自身结构特点和抗震设计方法中存在的缺陷.结合国外电力系统在应对地震灾害时的应急响应和震后快速恢复方法,提出了对我国现有电力设施进行抗震性能普查、薄弱环节进行抗震加固和重建改造,以及建立相应的应急响应机制的一系列措施.
Abstract:The malfunction of the anti-seismic design in electric power grid and its damages to electric power grid under 5?12 Wenchuan Earthquake are reviewed and the disaster causes are analyzed. Then,some drawbacks of the current electric power equipment and its anti-seismic design methods are summarized. Several new measures and suggestions to strengthen such drawbacks are put forward. Finally,such measures as the anti-seismic capacity general survey for current electric power equipment,seismic reinforcement for weak link and building a emergency response for electric power system,are proposed.
文章编号:20110509 中图分类号: 文献标志码:
基金项目:
作者 | 单位 | |
汪洋 | 上海电力学院经济与管理学院, 上海 200090 | hdtmwy@ 163.com |
杨太华 | 上海电力学院经济与管理学院, 上海 200090 | |
曹加良 | 同济大学结构工程与防灾研究所, 上海 200092 |
引用文本:
汪洋,杨太华,曹加良.我国电力系统的地震灾害及应对机制[J].上海电力大学学报,2011,27(5):451-454.
WANG Yang,YANG Tai-hua,CAO Jia-liang.Research on Seismic Disaster and Emergency Response of Electric Power Grid[J].Journal of Shanghai University of Electric Power,2011,27(5):451-454.
汪洋,杨太华,曹加良.我国电力系统的地震灾害及应对机制[J].上海电力大学学报,2011,27(5):451-454.
WANG Yang,YANG Tai-hua,CAO Jia-liang.Research on Seismic Disaster and Emergency Response of Electric Power Grid[J].Journal of Shanghai University of Electric Power,2011,27(5):451-454.