上海电力大学学报:2013,29(5):497-500,512
本文二维码信息
码上扫一扫!
循环冷却水水质稳定剂试验研究
(上海电力学院, 环境与化学工程学院, 上海 200090)
Pilot Study of Water Quality Stabilizer in Power Plant Circulating Cooling Water
(School of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, China)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 1006次   下载 712
投稿时间:2012-07-09    
中文摘要: 针对某电厂现场水样,投加不同水处理剂,进行静态阻垢试验和静态旋转挂片试验,比较各药剂的阻垢及缓蚀性能,筛选出适合该水质的水质稳定剂,确定其最佳控制参数,为电厂循环冷却水系统现场运行方案提供相关依据.
中文关键词: 循环冷却水  水质稳定剂  阻垢  缓蚀
Abstract:Static scale inhibition test,sample-revovled corrosion test,dynamic imitating test are conducted by adding diverse water treatment agents to the water used in a power plant circulating cooling water system. The research is used for screening the water quality stabilizer that is suitable for the given water through comparing agent function of scale inhibition and corrosion inhibition,and defining the best controlling parameter,which provides guidance for operation plan in power plant circulating cooling water system.