上海电力大学学报:2014,30(2):136-140
本文二维码信息
码上扫一扫!
320 MW机组脱硝改造方案及实施效果
(神华神皖安庆皖江发电有限责任公司)
320 MW Unit Denitrification Modification Method and Effect
(Shenhua Shenwan Anqing Wanjiang Power Generation Co., Ltd., Anqing 246005, China)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 1125次   下载 576
投稿时间:2014-01-07    
中文摘要: 论述了安徽某电厂2#锅炉采取低氮燃烧器改造、选择性催化还原相结合的脱硝改造方案及实施过程,改造完成后,经过有资质的第3方检验,锅炉出口氮氧化物浓度从550~650 mg/Nm3降至80 mg/Nm3以下,达到了新版国家标准的要求,取得了良好的社会效益.
Abstract:The 2# boiler of a certain power plant in Anhui Province adopts the scheme that includes the transformation of burner of low nitrogen and the transformation of selective catalytic reduction in two parts together,after the completion of the transformation by a qualified third party inspection.The boiler outlet NO<em>x concentration is cut down from 550~650 mg/Nm3 to below 80 mg/Nm3.It reaches a new national standard requirement,and gets a good social benefit.
文章编号:20140209     中图分类号:    文献标志码:
基金项目:
引用文本:
徐顺喜,吴志祥.320 MW机组脱硝改造方案及实施效果[J].上海电力大学学报,2014,30(2):136-140.
XU Shunxi,WU Zhixiang.320 MW Unit Denitrification Modification Method and Effect[J].Journal of Shanghai University of Electric Power,2014,30(2):136-140.