本文已被:浏览 1030次 下载 903次
投稿时间:2014-05-04
投稿时间:2014-05-04
中文摘要: 分析了发电厂在线钠表准确性检验存在的问题,介绍了一种在线钠表准确度检验装置,通过原子吸收分光光度计的对比实验,检测了该装置产生的低浓度标准溶液,并利用该装置分析了ThermoORION公司生产的2111LL型在线微钠表的在线检测准确度.试验结果表明,该装置可以提高在线钠表的可靠性和检验的准确性.
Abstract:The problems in accuracy tests of online sodium analyzers are analyzed, a test device for testing online sodium analyzer accuracy is introduced, the low concentration standard solution generated by the device in a comparison test with atomic absorption spectrophotometer is exammined, and the precision of the 2111 LL online sodium analyzer produced by Thermo ORION company through the utilization of the device is analyzed. The results prove that the device for testing the accuracy of the online sodium analyzer can improve its reliability and accuracy.
文章编号:20140416 中图分类号: 文献标志码:
基金项目:
作者 | 单位 | |
刘伟 | 贵州电力试验研究院化环所 | gzsyylw2053@sina.com |
顾雷 | 南京华天科技发展有限公司研发部 |
引用文本:
刘伟,顾雷.发电厂在线钠表的准确度检验[J].上海电力大学学报,2014,30(4):371-374.
LIU Wei,GU Lei.Accuracy Test of Online Sodium Analyzers in Power Plants[J].Journal of Shanghai University of Electric Power,2014,30(4):371-374.
刘伟,顾雷.发电厂在线钠表的准确度检验[J].上海电力大学学报,2014,30(4):371-374.
LIU Wei,GU Lei.Accuracy Test of Online Sodium Analyzers in Power Plants[J].Journal of Shanghai University of Electric Power,2014,30(4):371-374.