DOI:
Journal of ShangHai University of Electric Power :2010,26(1):31-35,40
View/Add Comment     Archive    Advanced search     HTML
←Previous   |   Next
600MW超临界燃煤机组SCR烟气脱硝工程实例
(1.国电铜陵发电有限公司, 安徽 铜陵 244153;2.上海电力学院, 上海 200090)
An Application Example of Selective Catalytic Reduction System in 600 MW Supercritical Coal-fired Units
(1.Guodian Tongling Power Generation Co., Ltd, Tongling 244153, China;2.Shanghai University of Electric Power, Shanghai 200090, China)
Abstract
Image-text
References
Similar literature
本文已被:浏览 694次   下载 632
Received:July 06, 2009    
中文摘要: 介绍了国电铜陵600 MW超临界燃煤机组安装脱硝装置项目的前期研究、主要设计特点、系统设计、调试运行,以及投产运行后的经济情况,得出了一系列火电项目加装脱硝设施建设与运行方面的参考意见.
Abstract:The flue gas denitrification device of the 600 MW supercritical coal-fired units are introduced in terms of its preliminary research,major design features,system designing,operational testing,as well the econimic value after it is put into operation. Some valuable suggestions are put forward regarding equipping the coal-fired projects with denitrification device.
文章编号:20100109     中图分类号:    文献标志码:
基金项目: