中文摘要: 分析了M701F燃气-蒸汽联合循环发电机组一次调频的工作原理,介绍了该机组进行一次调频的控制方式,通过动态扰动试验,总结了该类机组进行一次调频所具有的特点,为同类机组的一次调频提供参考.
Abstract:The working mechanismof the primary frequency modulation control mode and application of M701F combined cycle generation unit are introduced. The features of primary frequencyof the units of this kindare introduced,to the result that reference is providedfor the primary frequency of units of the same kind.