Journal of ShangHai University of Electric Power :2018,34(2):115-118
View/Add Comment     Archive    Advanced search     HTML
←Previous   |   Next
1 000 MW塔式锅炉炉内燃烧特性的数值模拟
(1.上海电力学院;2.华能(上海)电力检修有限责任公司)
Numerical Simulation of Combustion Characteristics in a 1 000 MW Tower Boiler
(1.Shanghai University of Electric Power, Shanghai 200090, China;2.Huaneng(Shanghai) Power Maintenance Co., Ltd, Shanghai 200942, China)
Abstract
Image-text
References
Similar literature
本文已被:浏览 1187次   下载 654
Received:March 06, 2018    
中文摘要: 利用FLUENT软件对某1 000 MW塔式锅炉的燃烧过程进行了数值模拟。结果表明:在额定工况下,温度在炉膛内呈左右对称分布,高温区出现在燃烧器区域的中上部;锅炉冷灰斗区域的温度最低;沿射流方向靠近下游水冷壁处的温度高、氧浓度低,在运行中要注意下游水冷壁区域的结渣情况。
中文关键词: 锅炉  四角切圆燃烧  偏置风  结渣  数值模拟
Abstract:In order to study the combustion of 1 000 MW tower boiler in operation,the combustion process of a 1 000 MW tower boiler is simulated by FLUENT software.The results show that under the BMCR working condition,the temperature is symmetrical distribution in the furnace and the high temperature region appears in the middle and upper part of the burner area.The temperature at the area of the furnace hopper is the lowest.The position close to downstream water-wall along the jet direction is easy to slag.
文章编号:20182004     中图分类号:    文献标志码:
基金项目:上海市科学技术委员会项目(18020501000)。
Reference text: