Journal of ShangHai University of Electric Power :2018,34(2):123-126
View/Add Comment     Archive    Advanced search     HTML
←Previous   |   Next
630 MW超临界机组脱硫氧化风机系统的优化节能运行研究
(安徽华电宿州发电有限公司)
Research on Desulfurization and Oxidation Fan System in a 630 MW Ultra Supercritical and Optimized Energy-saving Operation
(Anhui Huadian Suzhou Power Generation Co., Ltd., Suzhou 234101, China)
Abstract
Image-text
References
Similar literature
本文已被:浏览 1237次   下载 589
Received:June 21, 2016    
中文摘要: 在满足国家环保要求的前提下,为减少运行电耗,降低企业生产成本,研究了超临界机组脱硫氧化风机节能运行模式。理论计算和实际运行结果表明,将风机的运行方式由原先的两运一备变为一运两备后,解决了节能问题,具有一定的工程应用价值。
中文关键词: 超临界机组  风机  节能
Abstract:On the premise of meeting the requirements of the state environmental protection,to reduce the running power consumption and production cost,the supercritical unit oxidation desulfurization fan energy-saving operation mode is studied.Theoretical calculation and practical operation results show that when the fan operation mode changes from the state of two in operation with one in readiness to the state of one in operation with one in readiness the energy saving problem is solved,which has some engineering application value.