中文摘要: 本文通过循环水管网水力工况分析及凝汽器传热特性计算,得出了不同机组负荷、不同循环水进水温度下循泵的优化投用方案.
Abstract:By analizing the flow-network of circulating-water pipes and the heat transfer pattern of condensers, this paper describes the method of optimizing operating-water pumps where adopting blade-inadjustable pumps. And it presents the optimum operation program of circulating water pumps with various turbine loads and various inlet water tempretares.