中文摘要: 在对台州电厂N-7100型和N-17800型凝汽器钛管频繁泄漏原因进行分析的基础上,提出了解决的对策.通过实际改造,N-7100型和N-17800型凝汽器凝结水的各项指标均达到要求,基本解决了凝汽器钛管泄漏的问题,取得了良好的经济效益.
Abstract:In this paper,the problem of titanium-duct leakage of N-7100 and N-17800 condensers in Taizhou power plant is studied.Causes for the leakage are analyzed and countermeasures are put forward.Through practical modification,all data of N-7100 and N-17800 condensers meet the need.The problem of titanium-duct leakage is solved.Good economic efficiency is obtained.
keywords: condenser leakage reason analysis
文章编号:20060307 中图分类号: 文献标志码:
基金项目:
作者 | 单位 |
杨光明 | 安徽凤台发电厂, 安徽 凤台 230031 |
潘世汉 | 台州发电厂, 浙江 台州 318016 |
Author Name | Affiliation |
YANG Guang-ming | Fengtai Power Plant, Fengtai 230031, China |
PAN Shi-han | Taizhou Power Plant, Taizhou 318016, China |
引用文本:
杨光明,潘世汉.N-7100型和N-17800型凝汽器钛管泄漏原因及预防对策[J].上海电力大学学报,2006,22(3):225-228.
YANG Guang-ming,PAN Shi-han.Cause Analysis and Countermeasures of Titanium-Duct Leakage of N-7100 and N-17800 Condensers[J].Journal of Shanghai University of Electric Power,2006,22(3):225-228.
杨光明,潘世汉.N-7100型和N-17800型凝汽器钛管泄漏原因及预防对策[J].上海电力大学学报,2006,22(3):225-228.
YANG Guang-ming,PAN Shi-han.Cause Analysis and Countermeasures of Titanium-Duct Leakage of N-7100 and N-17800 Condensers[J].Journal of Shanghai University of Electric Power,2006,22(3):225-228.