DOI:
上海电力大学学报:2007,23(1):65-67
本文二维码信息
码上扫一扫!
大型定子水内冷发电机内冷水RH/RNa/ROH混床处理方法的探讨
(太仓港环保发电有限公司, 江苏 太仓 215433)
On the RH/RNa/ROH Multi-bed Processing Method for Big Stator Water-inner Cooling Generator Cooling Water
(Taicang Port Environmental Protection Generation Co.Ltd,Taicang 215433,China)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 865次   下载 535
投稿时间:2007-02-28    
中文摘要: 发电机内冷水水质不达标及因水质控制不当会引起铜导线腐蚀,近年来已引起发电厂的普遍重视.指出提高发电机内冷水系统的防腐能力的关键是提高内冷水的pH值.通过现场试验,验证了采用RH/RNa/ROH型混床对内冷水进行处理的可行性和有效性.
中文关键词: 发电机  内冷水  铜腐蚀  RH/RNa/ROH型混床  pH值
Abstract:Erosion of the copper wires may occur owing to non-tandard quality and inadequate control of the cooling water of the generator, which has caught the attention of certain power plants.It is put forward that the key to the improvement of the anti-erosion function of the cooling water system of the generator is to raise the pH value of the water.Based on field experiments, the feasibility and efficiency of processing cooling water by using the RH/RNa/ROH Multi-bed Processing method.
文章编号:20070117     中图分类号:    文献标志码:
基金项目:
引用文本:
李新学,夏恩专.大型定子水内冷发电机内冷水RH/RNa/ROH混床处理方法的探讨[J].上海电力大学学报,2007,23(1):65-67.
LI Xin-xue,XIA En-zhuan.On the RH/RNa/ROH Multi-bed Processing Method for Big Stator Water-inner Cooling Generator Cooling Water[J].Journal of Shanghai University of Electric Power,2007,23(1):65-67.