中文摘要: 接地网是保证电网安全运行的重要装置.分析了引起变电站接地网腐蚀的原因,介绍了关于接地材料的选择、电化学保护,以及防腐导电涂料的使用等接地网防腐蚀技术的研究进展.
Abstract:Grounding grid is an important device for electricity net to work safely.The objective of this paper is to analyze the reasons why the grounding grid could be in corrosion.Moreover,the paper introduces the techniques of protecting the grounding grid from corrosion,including the choice of grounding materials,the protection in electrochemistry and the use of conductive anti-corrosion paint.
keywords: substation grounding grid corrosion protection
文章编号:20090612 中图分类号: 文献标志码:
基金项目:
引用文本:
朱忠伟,吴一平,葛红花.变电站接地网腐蚀与防护研究进展[J].上海电力大学学报,2009,25(6):570-574.
ZHU Zhong-wei,WU Yi-ping,GE Hong-hua.Research of Corrosion and Protection for Grounding Grid in Substation[J].Journal of Shanghai University of Electric Power,2009,25(6):570-574.