本文已被:浏览 904次 下载 975次
投稿时间:2011-07-04
投稿时间:2011-07-04
中文摘要: 采用ANSYS软件对500 kV电力变压器高压绕组端部电场进行仿真计算,得到了端部电场和电位分布图,指出了端部电场最大电场强度值及其所在位置.通过改变静电环的曲率半径,减小了绝缘层表面的最大场强值,以优化电场分布并确定500 kV变压器主绝缘的结构尺寸,为变压器的设计和改进提供了参考依据.
Abstract:ANSYS software package is used to analyze and calculate the electric field intensity of500kV power transformer’s HV winding. The potential and electric field intensity distribution areobtained. The maximum of electric field intensity can be found and its location can be pointed out.The model is optimized by analyzing the electric field distribution and changing the curvature radiusof the electrostatic ring to reduce the maximum electric field intensity value of insulating layer,thereby optimizing the electric field distribution. These analyses and calculation provide a certainreference for designing the transformer’s structural dimensions of the main insulation of 500kVpower transformer.
keywords: ANSYS software power transformer terminal insulation electric field analysis structure optimization
文章编号:20120402 中图分类号: 文献标志码:
基金项目:国家自然科学基金(51007055);上海市教育委员会科研创新项目(12YZ141);上海高校选拔优秀青年教师科研专项基金(sdl10012)
作者 | 单位 | |
马爱清 | 上海电力学院电力与自动化工程学院, 上海 200090 | aqmab@ shiep.edu.cn. |
Author Name | Affiliation | |
ZHANG Zhou-sheng | School of Electric Power and Automation Engineering,Shanghai Universityof Electric Power,Shanghai 200090,China | aqmab@ shiep.edu.cn. |
引用文本:
马爱清.基于ANSYS的500kV电力变压器端部绝缘电场分析及结构优化[J].上海电力大学学报,2012,28(4):305-308.
ZHANG Zhou-sheng.Partial Discharge Signal Identification Methods andKey Technique of XLPE Power Cables[J].Journal of Shanghai University of Electric Power,2012,28(4):305-308.
马爱清.基于ANSYS的500kV电力变压器端部绝缘电场分析及结构优化[J].上海电力大学学报,2012,28(4):305-308.
ZHANG Zhou-sheng.Partial Discharge Signal Identification Methods andKey Technique of XLPE Power Cables[J].Journal of Shanghai University of Electric Power,2012,28(4):305-308.