上海电力大学学报:2012,28(5):431-434
本文二维码信息
码上扫一扫!
基于模糊综合评判的电力变压器绝缘老化诊断
(1.上海电力学院电力与自动化工程学院, 上海 200090;2.上海市电力公司嘉定供电公司, 上海 201800)
Diagnosis for Power Transformer Insulation Aging Based on Fuzzy Synthetic Evaluation
(1.School of Electric Power and Automation Engineering, Shanghai University of Electric Power, Shanghai 200090, China;2.Jiading Power Supply Company, Shanghai Municipal Electric Power Company, Shanghai 201800, China)
摘要
图/表
参考文献
本刊相似文献
All Journals 相似文献
All Journals 引证文献
本文已被:浏览 1019次   下载 502
投稿时间:2011-03-11    
中文摘要: 利用模糊综合评判理论,基于专家经验确定了各个参数的权重,最终建立了变压器绝缘老化综合评判的模型.通过实例证明,所建立的综合评判模型能正确有效地进行老化判断.
Abstract:By adopting the theory of fuzzy comprehensive evaluation,and based on the experience of experts,the weights of the various parameters are set up,and finally a comprehensive evaluation of transformer insulation aging models are established. Examples show that the comprehensive evaluation model can correctly decide on the aging problem.
文章编号:20120508     中图分类号:    文献标志码:
基金项目:上海市教育委员会重点学科建设项目(J51301)
引用文本:
江玉蓉,王霄峰,符杨,等.基于模糊综合评判的电力变压器绝缘老化诊断[J].上海电力大学学报,2012,28(5):431-434.
JIANG Yu-rong,WANG Xiao-feng,FU Yang,et al.Diagnosis for Power Transformer Insulation Aging Based on Fuzzy Synthetic Evaluation[J].Journal of Shanghai University of Electric Power,2012,28(5):431-434.