本文已被:浏览 952次 下载 537次
投稿时间:2013-09-18
投稿时间:2013-09-18
中文摘要: 设计了一种基于DSP的SF6监测系统,该系统利用红外气体传感器实现对SF6泄漏浓度的测量.根据传感器外围电路设计要求,对以TMS320F2812为核心的外围测试电路如显示电路、通信电路等进行了设计和编制.试验结果显示,该系统能够灵敏地检测到SF6泄漏,达到了设计要求.
Abstract:An SF6monitoring system based on DSP is designed,and the SF6infrared sensor is used to measure SF6leak of power equipment. Based on the demand of SF6infrared sensor interface circuit,the test circuit is designed in the core of TMS320F2812,such as SCI communication and LCD display etc. From the testing results,it can be seen that the whole system can be used to measure SF6leak accurately.
keywords: SF6 leak monitoring infrared sensor
文章编号:20130504 中图分类号: 文献标志码:
基金项目:
作者 | 单位 | |
阮浩洁 | 宁波北仑供电局, 浙江 宁波 315800 | |
张晓波 | 宁波北仑供电局, 浙江 宁波 315800 | |
段晓雷 | 宁波北仑供电局, 浙江 宁波 315800 | |
陈侠 | 上海电力学院, 上海 200090 | dzani14@163.com |
引用文本:
阮浩洁,张晓波,段晓雷,等.基于TMS320F2812的SF6泄漏监测系统的设计[J].上海电力大学学报,2013,29(5):429-432.
RUAN Haojie,ZHANG Xiaobo,DUAN Xiaolei,et al.Design of SF6Leak Monitoring System Based on TMS320F2812[J].Journal of Shanghai University of Electric Power,2013,29(5):429-432.
阮浩洁,张晓波,段晓雷,等.基于TMS320F2812的SF6泄漏监测系统的设计[J].上海电力大学学报,2013,29(5):429-432.
RUAN Haojie,ZHANG Xiaobo,DUAN Xiaolei,et al.Design of SF6Leak Monitoring System Based on TMS320F2812[J].Journal of Shanghai University of Electric Power,2013,29(5):429-432.