本文已被:浏览 796次 下载 618次
投稿时间:2013-02-25
投稿时间:2013-02-25
中文摘要: 对某电厂2台440 t/h锅炉管式空气预热器堵灰问题进行了计算和分析,指出了导致空气预热器堵灰的主要原因为烟气结露、烟气流速低与分布不均等.根据锅炉设计和运行特点,制定了加装围板提高空气预热器末端管壁温度、封堵部分换热管以及增加导流板等可行的技术改造方案,改造后的机组实现了长周期的稳定运行.
Abstract:The ash plugging and its reasons of the shell-and-tube air preheaters of two 440 t/h boilers are presented and analyzed. The reasons include the condensation,low velocity and uneven distribution of flue gas in the preheaters. According to the boiler design and operation characters,the renovation measures are presented,which are increasing the temperatures at the end of heat exchange tubes,plugging some heat exchange tubes and installing baffles. Finally,satisfactory results are obtained after renovation.
文章编号:20130511 中图分类号: 文献标志码:
基金项目:
作者 | 单位 | |
姜浩 | 华北电力大学, 北京 102206 华能新疆能源开发有限公司, 新疆 乌鲁木齐 830017 | hnxjjh@163.com |
秦兵 | 华能新疆阜康热电有限责任公司, 新疆 阜康 831500 |
引用文本:
姜浩,秦兵.440t/h锅炉管式空预器堵灰原因分析与治理[J].上海电力大学学报,2013,29(5):455-458.
JIANG Hao,QIN Bing.Analysis and Treatment of Ash Plugging of the Shell-and-Tube Air Preheater of the 440 t/h Boiler[J].Journal of Shanghai University of Electric Power,2013,29(5):455-458.
姜浩,秦兵.440t/h锅炉管式空预器堵灰原因分析与治理[J].上海电力大学学报,2013,29(5):455-458.
JIANG Hao,QIN Bing.Analysis and Treatment of Ash Plugging of the Shell-and-Tube Air Preheater of the 440 t/h Boiler[J].Journal of Shanghai University of Electric Power,2013,29(5):455-458.